CERTA heavy channel system

KE heavy channel.

Corrosion protection: hot-dip galvanized

Application: Constructing beams (horizontal). Constructing pillars. Constructing various frames and spatial structures using other system components (connectors, supports, brackets, rungs)

Installation method: Installation of CERTA system components to the KE channel is carried out as follows:- in case of elements installed inside the channel through longitudinal holes, - in case of elements installed outside through Ø9.1 mm round holes One hole is intended for only one self-threading bolt. The number of bolts used for installation depends on the type of product being installed. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm

S support for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a KE heavy channel into the structure of the building (wall, floor, ceiling). Installation with a KE heavy channel into a structure made of channels. Creating various structures (such as gates) or spatial structures, attached to the structure of the building (wall, floor, ceiling) or to other structures made of KE channels

Installation method: The CERTA system element installed on the outside of the KE channel is bolted through slotted holes (in the support for the element) using XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Products installed on the outside of the channel should be fastened with four bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Use two bolts opposite each other for the fastener mounted inside the channel.

SK45 channel support for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a heavy channel into the structure of the building (wall, floor, ceiling) at an angle of 45 degrees. Installation with a heavy channel into the structure made of channels at an angle of 45 degrees

Installation method: The CERTA system element installed on the outside of the channel is attached through longitudinal holes (in the support for the element) with XPCSPM10X21 self-threading bolts fastened into Ø9.1mm round holes in the channel. One hole is intended for only one self-threading bolt. Products installed on the outside of the channel should be fastened with four bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Use two bolts opposite each other for the fastener mounted inside the channel.

LKZ corner connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: For perpendicular connecting of KE heavy channels.. An additional hole allows stays to be constructed for the purpose of reinforcing the footing. For perpendicular connecting of brackets to KE heavy channels

Installation method: The CERTA system element installed on the outside of the KE channel is bolted through slotted holes (in the support for the element) using XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm.

SN support for KE channel.

Corrosion protection: hot-dip galvanized

Application: assembly with a structural profile for the object’s structure (wall, floor, ceiling). assembly with a structural profile for a profile-based structure. creation of various structures (such as a gate) or spatial ones, mounted to the object’s structure (wall, floor, ceiling) or to other profile-based structures (ke profiles). the placement of the connector allows for installation at the edge.

Installation method: mounted on the outside of the ke profile, the CERTA system element is screwed through longitudinal holes (in the base of the element) with self-tapping screws xpcspm10x21, which are screwed into round holes Ø9.1 mm in the profile. one hole is intended for only one self-tapping screw. products mounted on the outside of the profile should be screwed with four screws. the xpcspm10x21 screw should be tightened with a torque of 60 nm. for the connector mounted inside the profile, use two screws opposite each other.

LT connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: For perpendicular connecting of KE heavy channels

Installation method: The CERTA system element installed on the outside of the channel is bolted through slotted holes with XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Fasten the fitting to the outside of the channels with eight bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm.

LK connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: For perpendicular connecting of KE heavy channels.. An additional hole allows stays to be constructed for the purpose of reinforcing the footing. For perpendicular connecting of brackets to KE heavy channels

Installation method: The CERTA system element installed on the outside of the channel is bolted through slotted holes with XPCSPM10X21 self-threading bolts fastened into Ø9.1 mm round holes in the channel. One hole is intended for only one self-threading bolt. Fasten the bracket with a minimum of six self-threading bolts using the slotted holes. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm.

Beam clamp KLM for KE channel.

Corrosion protection: hot-dip galvanized

Application: Installation with a KE heavy channel into the structure of the building (wall, floor, ceiling). Installation with a KE heavy channel into a structure made of channels

Installation method: Place a U-bolt around the KE channel and secure it to the structural profile with a clamp by tightening two nuts.

LW channel connector for KE channel.

Corrosion protection: hot-dip galvanized

Application: Butt connecting of KE heavy channels. Butt connecting of consoles to KE heavy channels

Installation method: Installed inside the KE channel, it is fastened through slotted holes in the channel to round holes in the connector. The connector should be evenly distributed within the channel — both channels connected should have the same number of holes with the same length. Bolt each channel with four bolts, two opposite each other.

STS Support for KE channel.

Corrosion protection: zinc flake coating

Application: For connecting 41mm wide mounting channels to CERTA channels. Allows for self-assembly of mounting channels with supports (brackets) and construction of fastening systems

Installation method: The CERTA system element installed on the outside of the channel is attached through longitudinal holes (in the support for the element) with XPCSPM10X21 self-threading bolts fastened into Ø9.1mm round holes in the channel. One hole is intended for only one self-threading bolt. Products installed on the outside of the channel should be fastened with four bolts. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Slide the NICZUK system channel into the saddle section and tighten the fastening bolts.

SS support for KE channel.

Corrosion protection: hot-dip galvanized

Application: assembly with structural profile to existing steel structures of the object (pillars, beams, sheet metal) by welding. Creation of a variety of structures (gate-type) or spatial structures attached to the object's steel structures (columns, beams, sheet metal) by welding.

Installation method: assembly to existing steel structures by welding. Caution: Take into account in the assembly method the preparation of the surface to be welded of the parts to be joined. Insert the KE structural profile onto the internal connector as far as it will go and fasten with self-tapping screws (two screws opposite each other).

PM threaded rod base plate M8/10, M12/16.

Corrosion protection: zinc flake coating

Application: For installation of fixed points on Certa channel constructions

Installation method: The CERTA system element installed on the outside of the channel is attached through longitudinal holes (in the support for the element) with XPCSPM10X21 self-threading bolts fastened into Ø9.1mm round holes in the channel. One hole is intended for only one self-threading bolt. Tighten the XPCSPM10X21 bolt with a torque of 60 Nm. Two bolts should be used.